7SJ82 Over Current Protection

7SJ82 Over Current Protection

  • Detection and selective 3-pole tripping of short circuits in electrical equipment of star networks, lines with infeed at one or two ends, parallel lines and open-circuited or closed ring systems of all voltage levels
  • Detection of ground faults in isolated or arc-suppression-coil-ground power systems in star, ring, or meshed arrangement
  • Backup protection for differential protection devices of all kind for lines, transformers, generators, motors, and busbars
  • Protection and monitoring of simple capacitor banks
  • Phasor Measurement Unit (PMU)
  • Reverse-power protection
  • Load shedding applications
  • Automatic switchover
  • Regulation or control of power transformers (two-winding transformers)
  • Acquisition and recording of power quality data in the medium voltage and subordinate low voltage network

 

 

 

 

 

 

 

Main function:

  • Feeder and overcurrent protection for all voltage levels

Inputs and outputs:

  • 4 current transformers,
  • 4 voltage transformers (optional),
  • 11 or 23 binary inputs,
  • 9 or 16 binary outputs,

or

  • 8 current transformers,
  • 7 binary inputs,
  • 7 binary outputs

Hardware flexibility:

  • Different hardware quantity structures for binary inputs and outputs are available in the 1/3 base module. Adding 1/6 expansion modules is not possible; available with large or small display.

Housing width:

  • 1/3 × 19 inches

Function

DIGSI 5 permits all functions to be configured and combined as required.

  • Directional and non-directional overcurrent protection with additional functions
  • Optimized tripping times due to directional comparison and protection data communication
  • Detection of ground faults of any type in compensated or isolated electrical power systems using the following functions: 3I0>, V0>, transient ground fault, cos φ, sin φ, dir. detection of intermittent ground faults, harmonic detection and admittance measurement
  • Detection of intermittent ground faults with automatic blocking of static measuring functions, to avoid message and fault record flooding
  • Ground fault detection using the pulse detection method
  • Arc protection
  • Overvoltage and undervoltage protection
  • Frequency protection and frequency change protection for load shedding applications
  • Automatic frequency relief for underfrequency load shedding, taking changed infeed conditions due to decentralized power generation into consideration
  • Power protection, configurable as active or reactive power protection
  • Protection functions for capacitor banks, such as overcurrent, overload, current unbalance, peak overvoltage, or differential protection
  • Directional reactive power undervoltage protection (QU protection)
  • Control, synchrocheck and switchgear interlocking protection, circuit-breaker failure protection
  • Circuit-Breaker Failure Protection
  • Circuit breaker reignition monitoring
  • Graphical logic editor to create powerful automation functions in the device
  • Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as peak overvoltage protection for capacitors) and operational measured values
  • PQ-Basic: voltage unbalance; voltage changes: overvoltage, dip, interruption; TDD, THD and Harmonics
  • Single-line representation in small or large display
  • Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
  • 2 optional, pluggable communication modules, usable for different and redundant protocols (IEC 61850-8-1, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO)
  • Serial protection data communication via optical fibers, two-wire connections and communication networks  (IEEE C37.94, and others), including automatic switchover between ring and chain topology
  • Reliable data transmission via PRP and HSR redundancy protocols
  • Extensive cybersecurity functionality, such as role-based access control (RBAC), protocolling security-related events, signed firmware or signed firmware or authenticated network access IEEE 802.1X
  • Simple, quick and secure access to the device via a standard Web browser to display all information and diagnostic data, as well as vector diagrams, single-line and device display pages
  • Whitepaper Phasor Measurement Unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
  • Time synchronization using IEEE 1588
  • Control of Power Transformers
  • Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
  • Auxiliary functions for simple tests and commissioning

Brand

SIEMENS

Siemens Proven protection relays series for applications and voltage levels.
Transforming Industries with Cutting-Edge Solutions

Buy Now or Discuss Your Customized Needs with Us!

Explore the World of Mechanical, Electrical, Control Instruments, and Power Transmission Technologies for Enhanced Performance
Scroll to Top
Open chat
Welcome to PT ELEKTRIKA PERSADA SOLUSINDO don't hesitate to contact us and one of our experts will be in touch shortly