7SA87 Distance protection

7SA87 Distance protection

Main function:
Distance protection
Interoperability of SIPROTEC 5 and SIPROTEC 4 line protection devices
Tripping:
1-pole and 3-pole, minimum tripping time: 9 ms
Inputs and outputs:
12 predefined standard variants with
4/4 or 8/8 current transformers / voltage transformers,
5 to 31 binary inputs,
8 to 46 binary outputs
Hardware flexibility:
Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system
Width of housing:
1/3 × 19 inches to 2/1 × 19 inches

DIGSI 5 permits all functions to be configured and combined as required.

  • Minimum tripping time: 9 ms
  • 6 independent measuring loops (6-system distance protection)
  • Several distance-protection functions can be selected: Classic, reactance method (RMD), impedance protection for transformers
  • Directional backup protection and various additional functions
  • Detection of ground faults of any type in compensated or isolated electrical power systems using the following functions: 3I0>, V0>, transient ground fault, cos φ, sin φ, dir. Detection of intermittent ground faults harmonic detection and admittance measurement
  • Ground fault detection using the pulse detection method
  • Adaptive power-swing blocking, out-of-step protection
  • Detection of current-transformer saturation for fast tripping with high accuracy
  • Fault locator Plus for accurate fault location with inhomogenous line sections and targeted automatic overhead line section reclosing (AREC)
  • Arc protection
  • Automatic frequency relief for underfrequency load shedding, taking changed infeed conditions due to decentralized power generation into consideration
  • Power protection, configurable as active or reactive power protection
  • Directional reactive power undervoltage protection (QU protection)
  • Detection of current and voltage signals up to the 50th harmonic with high accuracy for selected protection functions (such as thermal overload protection) and operational measured values
  • PQ-Basic: voltage unbalance; voltage changes: overvoltage, dip, interruption; TDD, THD and Harmonics
  • 1-pole automatic reclosing function with detection secondary arc (SAD)
  • Point-on-wave switching
  • Control, synchrocheck and switchgear interlocking protection
  • Graphical logic editor to create powerful automation functions in the device
  • Single-line representation in small or large display
  • Integrated electrical Ethernet RJ45 for DIGSI 5 and IEC 61850 (reporting and GOOSE)
  • Up to 4 pluggable communication modules, usable for different and redundant protocols (IEC 61850-8-1, IEC 61850-9-2 Client, IEC 60870-5-103, IEC 60870-5-104, Modbus TCP, DNP3 serial and TCP, PROFINET IO, PROFINET IO S2 redundancy)
  • Virtual network sharing (IEEE 802.1Q – VLAN)
  • Serial protection data communication via optical fibers, two-wire connections and communication networks (IEEE C37.94, and others), including automatic switchover between ring and chain topology
  • Reliable data transmission via PRP and HSR redundancy protocols
  • Extensive cybersecurity functionality, such as role-based access control (RBAC), protocolling security-related events, signed firmware or authenticated network access IEEE 802.1X
  • Simple, quick and secure access to the device via a standard Web browser to display all information and diagnostic data, as well as vector diagrams, single-line and device display pages
  • Phasor measurement unit (PMU) for synchrophasor measured values and IEEE C37.118 protocol
  • Time synchronization using IEEE 1588
  • Powerful fault recording (buffer for a max. record time of 80 sec. at 8 kHz or 320 sec. at 2 kHz)
  • Auxiliary functions for simple tests and commissioning
  • Flexibly adjustable I/O quantity structure within the scope of the SIPROTEC 5 modular system

 

 

Brand

SIEMENS

Siemens Proven protection relays series for applications and voltage levels.
Transforming Industries with Cutting-Edge Solutions

Buy Now or Discuss Your Customized Needs with Us!

Explore the World of Mechanical, Electrical, Control Instruments, and Power Transmission Technologies for Enhanced Performance
Scroll to Top
Open chat
Welcome to PT ELEKTRIKA PERSADA SOLUSINDO don't hesitate to contact us and one of our experts will be in touch shortly